NOVOFLEX | Fire Retardant Cable Ties

Flame-resistant fastening for critical safety environments

Designed for fire-sensitive industrial and public infrastructure applications where cable management systems must minimize flame spread, smoke generation, and toxic emissions during fire exposure.

Request a Quote
Fire Retardant Cable Ties

Key Features

  • UL94V-0 flame-retardant performance
  • Halogen-free low smoke formulation
  • Reliable fastening under heat exposure
  • Designed for safety-critical installations
  • Suitable for public infrastructure and transit systems
Fire Retardant Cable Ties technical drawing

Technical Specifications

  • Material: UL-Listed Nylon 6.6
  • Flammability Rating: UL94V-0
  • Operating Temperature: -25°C to +85°C
  • Attributes: Halogen-Free
  • Standard Colour: White
  • Installation Type: Self-Locking Cable Tie

Product Dimensions

Novoflex Part No. Length (A) - mm Width (B) - mm Thickness (C) - mm Min Loop Tensile Strength (kgf) Max Bundle Dia - mm Standard Packing (Nos) Quantity Select
CPS 100 FR 100 2.5 1 8 24 1000
CPSS 150 FR 150 2.5 1.1 8 40 1000
CPSS 200 FR 200 2.5 1.2 8 55 1000
CPS 30150 FR 150 3 1.1 12 38 1000
CPS 150 FR 150 3.6 1.2 14 36 1000
CPS 30200 FR 200 3 1.1 12 54 100
CPS 200 FR 200 3.6 1.2 14 54 100
CPS 250 FR 250 3.6 1.2 14 70 100
CPSS 300 FR 300 3.6 1.2 14 86 100
CPSS 370 FR 370 3.6 1.2 14 108 100
CP 200 FR 200 4.7 1.2 22 50 100
CP 250 FR 250 4.7 1.3 22 64 100
CPS 300 FR 300 4.7 1.3 22 82 100
CPS 368 FR 368 4.7 1.3 22 103 100
CPS 450 FR 450 4.8 1.4 22 130 100
CPS 550 FR 550 4.6 1.3 22 162 100
CP 150 HD FR 150 7.5 1.5 55 32 100
CP 200 HD FR 200 7.5 1.5 55 49 100
CP 250 HD FR 250 7.5 1.5 55 65 100
CP 300 FR 300 7.6 1.6 55 76 100
CP 380 FR 380 7.6 1.5 55 108 100
CP 450 FR 450 7.5 1.6 55 125 100
CP 550 FR 550 9 1.8 80 156 100
CP 610 FR 610 9 1.8 80 171 100
CP 750 FR 750 9 1.8 80 219 100
CP 920 FR 920 9 1.8 80 275 100
CP 650 EHD FR 650 12.2 2 90 185 100

Standard & Custom Colours

Applications

  • Railway stations and tunnels
  • Mass transit vehicles
  • Oil and gas rigs
  • Public infrastructure projects
  • Electrical control systems
  • Safety-critical cable management installations

Use When

  • Fire safety compliance is critical
  • Low smoke emission is required
  • Public or enclosed environments are involved
  • Flame propagation risks must be minimized

Avoid When

  • Operating temperatures exceed specified limits
  • Stainless steel fastening systems are required
  • Heavy mechanical load applications exceed design parameters
  • Extreme outdoor UV exposure requires specialized UV formulations

Why Novoflex

Novoflex engineers cable management systems for environments where safety performance is as critical as mechanical reliability. By combining flame-retardant materials with industrial fastening performance, Novoflex products help reduce fire-related risks across infrastructure and transportation systems.NOVOFLEX |